Re: 1571/1581 Sources: Macro WDTEST inserting NOP before reading WD177x status register / writing command register

From: Francesco Messineo <francesco.messineo_at_gmail.com>
Date: Sat, 12 Mar 2022 12:00:49 +0100
Message-ID: <CAESs-_y55AZ6r-eEr2DXoD0q6nR8XKDfg301d71Hs-mUh9a2Tg_at_mail.gmail.com>
On Sat, Mar 12, 2022 at 11:41 AM Gerrit Heitsch
<gerrit_at_laosinh.s.bawue.de> wrote:
>

> Possible... But in the 1581 they use PHI2, at least according to the
> schematics. Also, so far I have never seen a WD1770 in a 1581, the ones
> I have seen used the WD1772 or VL1772.

I've seen the schematic, this is a good point, they correctly used
phi2's high phase this time,
it means using phi1's low phase wasn't such a wise choice after all :)
Maybe they've left the same NOP macro just for laziness?
I think the definitive answers can be had by just recompiling without
the NOPs and check
what happens (after making sure the schematics agree with the actual circuit).
Frank
Received on 2022-03-12 13:00:07