Re: CBM 8250LP update (hints welcome)

From: Francesco Messineo <francesco.messineo_at_gmail.com>
Date: Sun, 12 Feb 2023 20:31:39 +0100
Message-ID: <CAESs-_z5U4+36Q97RMh4f9DcTWM=X3pE+=hi8G395LjWmU575w_at_mail.gmail.com>
On Sun, Feb 12, 2023 at 3:52 PM <afachat_at_gmx.de> wrote:

> > no idea, the 4 heads are switched by diodes, so the gain is fixed at
> > the preamplifier for all heads.
> > Since also the write signal was different, I think that the head
> > somehow has developed some crack on the ferrite core, or otherwise
> > another mechanical fault that doesn't alter the resistance but does
> > alter the inductive properties.
> > Of course you might have a slightly misaligned top head, but I don't
> > recommend fiddling with that alignment if you don't have the right
> > tools (programs, reference disk) and patience.
> > It is scary that the low profile 100 tpi drives seem to have this
> > tendency, they're extremely rare. However I think one could
> > try to transplant an HD 96 tpi head (if a mechanically compatible HD
> > head does exist in the first place).
>
> It is indeed scary. One other possible cause I heard someone mentioned was
> that possibly the pressure of the upper head is somehow reduced due to
> mechanical fatigue in the springs that push the head down. This would (could)
> result in less magnetic flux. This could have been caused by storing the drives
> with the lid open.

no, that was happening on some 1571s I serviced a while ago, restoring
the proper spring action would
restore a perfect read/write capability. Although it was more of head
angled and not perfectly parallel to the disk surface.

>
> What do you think? Could this be a reason?
> (maybe a test would be to add a small weight on the upper head and re-run the
> tests with the scope attached.

pressure and head inclination was the first thing I thought of and I
tried to increase the pressure and slightly vary the head inclination,
nothing changed, or better, nothing improved, it turns out that
anything I tried actually made the signal even worse. If you watch the
read/write waveform video, the one with the scope vertical gain low
enough to show the actual write signal, you can see it looks too
"spike-y" when writing to the top head, write interval always happen
before a read interval on the same head, so it's easy to tell what
head is writing/reading to/from. I think the only explanation for
distorted
voltage waveform is a change in the inductance properties. Of course I
may be wrong, that's why I asked for hints in the first place.

Frank

> André
>
> > HTH
> > Frank IZ8DWF
> >
> > > André
> > >
> > > On Freitag, 6. Januar 2023 22:06:42 CET Francesco Messineo wrote:
> > > > Hi all,
> > > > just a little update on the 8250LP drive I started some weeks ago.
> > > > Basically, when I started, it seemed like the 6502 "FDC" would not
> > > > execute any meaningful code. I found it had a dead PHI1 output, but
> > > > would work fine into a PET. Also I've verified that PHI1 isn't
> > > > connected on both the 6502s on these drives. In the end, by swapping
> > > > the two 6502, the 8250LP started to have some life.
> > > > It would however not read the disks (2) formatted with another 8250
> > > > (non LP) that I received together with the unit to be serviced (I
> > > > don't have any 100tpi drive myself).
> > > > I've changed the capacitors on the Panasonic mechanics and verified
> > > > that the nearby traces weren't damaged, I've removed the darkned
> > > > solder mask around some leaking caps and re-tinned the traces. I've
> > > > then verified and slightly tuned the spindle speed on both drives
> > > > using the index sensor that I wired to 5V with a pullup resistor and
> > > > ground, the sensors on both drives are not used by the Commodore
> > > > digital board but are wired to pins 21 and 22 of each drive's
> > > > connector. I've found both drives to have 201ms interval between index
> > > > pulses, so I slightly tuned both to have 200ms nominal pulse interval.
> > > > I believe -/+ 3ms is ok however.
> > > > I've then tried formatting new floppies and drive 1 could complete the
> > > > format on just about any floppy I tried (more than 20 of them, never
> > > > failed one). However drive 0 would never finish formatting even on
> > > > de-gaussed media.
> > > > I've identified the problem of drive 0 to be a marginal or defective
> > > > r/w coil on head 1, see these short videos:
> > > > https://www.youtube.com/watch?v=_IWwMZAJjcI
> > > > https://www.youtube.com/watch?v=BsykFp8qZw4
> > > > https://www.youtube.com/watch?v=fn6r5pwQEqo
> > > >
> > > > The first one is read signal on drive 1, the format routine formats
> > > > first the lower side (head 0), then the upper side (head 1) then step
> > > > to the next track, You see there's no difference between the read
> > > > signal on head0/head1 on the first video, this is drive 1. The
> > > > interval when the signal disappears is a write phase, the signal is
> > > > too big to be seen with the vertical scale I was using.
> > > > Second video is drive 0 attempting to format, there's a noticeable
> > > > difference between head 0 (normal) signal and head 1. Of course, as
> > > > the drive progresses to inner traces, the radial speed of the media
> > > > decreases and the signal gets eventually too low.
> > > > Third video uses a lower vertical scale on the scope so also the write
> > > > waveform is showed. The write waveform is also slightly different when
> > > > it's switched to head 1.
> > > > Of course I've tried to swap the drives to exclude head select diode
> > > > issues on the analog board.
> > > > Out of desperation I've also tried to see if I could re-align the
> > > > upper head on drive 0. This isn't something to be attempted without a
> > > > reference disk and the right programs on 100 tpi drives, but after a
> > > > few hours tweaking the head position (I've got a macro picture of the
> > > > mounting position before starting), I haven't at least made it worse.
> > > > Drive 0 is still able to read all tracks on a disk formatted by drive
> > > > 1, albeit with some occasional head bumps on media having a not
> > > > brilliant S/N (and only when reading tracks on head 1).
> > > >
> > > > Now, the really puzzling part is: why I can't read the disks formatted
> > > > on the other 8250? All I get is 20 READ ERROR 39 0
> > > > Things that I've checked:
> > > > DS0/1 start at 1/1 then change at tracks 40, 54, 65
> > > > The GCR rom has the correct dump.
> > > > I've written a program that leaves the motor on, and can step in or
> > > > out by pressing a key on the PET, it seems the disks formatted on the
> > > > other 8250 have lower signal (as if alignment isn't really spot-on)
> > > > but the analog signal isn't too bad to justify a read error anyway.
> > > > Sync is clearly recognized or I would get a 21 and not a 20.
> > > > Is there something else I'm missing? The likely explanation would be
> > > > that two drives in the 8250LP have exact track alignment and two
> > > > drives in an 8250 also have exact alignment between them but one pair
> > > > is badly out of alignment?
> > > > This seems really unlikely to me.
> > > > Any hint is welcome.
> > > > Frank IZ8DWF
>
>
>
>
>
Received on 2023-02-12 21:00:03