RE: 1541/2031 combo adapter

From: Baltissen, GJPAA (Ruud) <"Baltissen,>
Date: Thu, 22 Oct 2020 05:10:42 +0000
Message-ID: <AM6PR10MB2360082871A832CE6CE823B8E11D0_at_AM6PR10MB2360.EURPRD10.PROD.OUTLOOK.COM>
Hallo Jim,


> Site is (was) at https://dl2dw.de/en/diy-projects/commodore/50-trimod-cbm-adapter (sadly, looks like site is down for maintenance)

Then it is down for months already. I last visited in June to check something, I bought one of the PCBs, and it was down then as well.

> Thus, it's unclear if the resulting patched ROM is 4040/2031 compatible or not.

The difference is the size of bytes in the gap between the header and the data. IIRC the -02 ROM and earlier have 8 bytes, the -03 nine. Reading should never be a problem. According several sources writing can. I myself cannot remember having any trouble when using 4040 disks in a 1541 and vice versa. But that was before I heard about the possible problem.
I assume that someone wants to convert a 1541 to a 2031 because not having one or a 4040. If he wants to exchange data with a C64/128 then only the better.


With kind regards / met vriendelijke groet, Ruud Baltissen

http://www.baltissen.org<http://www.baltissen.org/>





De informatie in dit e-mailbericht is vertrouwelijk en uitsluitend bestemd voor de
geadresseerde. Wanneer u dit bericht per abuis ontvangt, verzoeken wij u contact op te
nemen met de afzender per kerende e-mail. Verder verzoeken wij u in dat geval dit
e-mailbericht te vernietigen en de inhoud ervan aan niemand openbaar te maken.
Wij aanvaarden geen aansprakelijkheid voor onjuiste, onvolledige dan wel ontijdige
overbrenging van de inhoud van een verzonden e-mailbericht, noch voor daarbij
overgebrachte virussen.

APG Groep N.V. is gevestigd te Heerlen en is ingeschreven in het
handelsregister van de Kamer van Koophandel Limburg onder nummer 14099617


The information contained in this e-mail is confidential and may be privileged.
It may be read, copied and used only by the intended recipient.
If you have received it in error, please contact the sender immediately by
return e-mail; please delete in this case the e-mail and do not disclose its
contents to any person. We don't accept liability for any errors, omissions,
delays of receipt or viruses in the contents of this message which arise as a
result of e-mail transmission.

APG Groep N.V. is registered in the trade register of the Chamber
of Commerce Limburg, The Netherlands, registration number: 14099617
Received on 2020-10-22 08:00:03

Archive generated by hypermail 2.3.0.