Re: SX-clocks (another one)

From: Michał Pleban <lists_at_michau.name>
Date: Fri, 03 May 2013 20:00:45 +0200
Message-ID: <5183FB4D.2020809@michau.name>
Hello!

silverdr@wfmh.org.pl wrote:

>   if(pal)
>     wait_full_rasters(25);  // This can be done by simply polling the VIC
>   else
>     wait_full_rasters(30);

Why use polling when you have the raster interrupt? ;-)

> but if someone knows why this would not work (reliably) or knows a better method, I would be glad to hear!

I would use CIA counters instead of VIC frames, it will be faster.

Regards,
Michau.



       Message was sent through the cbm-hackers mailing list