RE: C64 cluster

ruud.baltissen_at_abp.nl
Date: 2007-11-12 08:06:41

Hallo Jim,
 

>> telling the system that the network is alive by pulling it High. The
>> first C64 to be started sees a (H) on this line and waits for its
>   
> Don't you mean L?

Yep, indeed. I thought that I changed that. The first idea was starting
with (H) and pulling it to (L) but then I got this idea of using (H) as
active signal so it also could be used as a (small) power source. But
now it seems I forgot to change the first (H).


> This suffers if more than one machine power up at the same time

The idea was to power-on only _one_ machine by hand and this one sees a
(L) and thus asks if it should start the network software. Witht the
right electronics installed, the rest of the C64's will start-up and see
a (H).


> I was rather hoping something like the IEC ATN line....

No problem, but then, as said, a collision detection is needed. But
whether to use collision detection, master/slave, token ring or another
solution is a matter of SW and IMHO we can discuss that thoroughly after
we have decided on the hardware.


--
     ___
    / __|__
   / /  |_/     Groetjes, Ruud
   \ \__|_\
    \___|       URL: Ruud.C64.org

 
De informatie in dit e-mailbericht is vertrouwelijk en uitsluitend bestemd voor de geadresseerde. Wanneer u dit bericht per abuis ontvangt, verzoeken wij u contact op te nemen met de afzender per kerende e-mail. Verder verzoeken wij u in dat geval dit e-mailbericht te vernietigen en de inhoud ervan aan niemand openbaar te maken. Wij aanvaarden geen aansprakelijkheid voor onjuiste, onvolledige dan wel ontijdige overbrenging van de inhoud van een verzonden e-mailbericht, noch voor daarbij overgebrachte virussen.

Stichting Pensioenfonds ABP is gevestigd te Heerlen en ingeschreven bij de Kamer van Koophandel Zuid Limburg onder nummer: 41074000


The information contained in this e-mail is confidential and may be privileged. It may be read, copied and used only by the intended recipient. If you have received it in error, please contact the sender immediately by return e-mail; please delete in this case the e-mail and do not disclose its contents to any person. We don't accept liability for any errors, omissions, delays of receipt or viruses in the contents of this message which arise as a result of e-mail transmission.

Stichting Pensioenfonds ABP, having its registered office at Heerlen, is registered in the Traderegister of the Chamber of Commerce Zuid Limburg (Maastricht), the Netherlands, registration number: 41074000





       Message was sent through the cbm-hackers mailing list

Archive generated by hypermail pre-2.1.8.